Biomass Boiler

LSG Biomass Steam Generator — Vertical Type

Turn jute waste into steam.
Features
Vertical biomass steam generator
Water tube heating structure
Double-layer grate design
Jute waste fabric fuel use
Compatible with solid combustibles
Fully assembled machine body

Description

The LSG Biomass Steam Generator is designed for facilities that want to reuse jute waste fabric or compatible solid combustible materials as fuel. Its water tube structure and double-layer grate design support combustion, heat transfer, and steam generation within a compact machine body. The system mainly uses jute waste fabric as fuel and can be mixed with other compatible solid combustibles depending on material condition. High-moisture materials should be dried and processed into smaller pieces before use. It is suitable for factories seeking a compact biomass steam system using waste fabric or biomass materials.

Added to Inquiry list.

Specifications

Category Item Unit LSG1-0.8-FL LSG1.5-0.8-FL LSG2-0.8-FL
Specification Rated Evaporation kg/h 1000 1500 2000
Rated Steam Pressure MPa 0.8
Rated Steam Temperature 175
Exhaust Temperature ≤230
Water Temperature 20
Boiler Water Volume 2.8 3.3 3.6
Total Power Consumption kW 18 25 33
Insulation Soft Water Tank Volume 2 3
Design Thermal Efficiency % 88
Heat of Combustion kcal/kg 4600
Fuel Consumption Fuel Consumption kg/h 160 240 320
Blower Blower Model 9-26-4.5A-7.5KW 9-26-4.5A-11KW 9-26-5A-15KW
Fan Fan Model Y6-30-7.5C-7.5KW Y6-30-7.5C-11KW Y6-30-7.5C-7.5KW
Heated Surface Ontology 40 53 65
Pump Input Power kW 3P 380V
Pipe Main Steam Valve Diameter DN 50 65
Water Inlet Diameter DN 40 50
Safety Valve Diameter DN 40 50 65
Blowoff Valve Diameter mm 40
Chimney Φmm 350 400
Installation Size Length mm 10000 11000 12000
Width mm 6000 6500
Height mm 5500 6000
Maximum Shipping Size Length mm 1850 2050
Width mm 1850 2050
Height mm 3600 3700 3950
*Remarks: Without automatic feeding, the length can be reduced by 1500 mm. If the boiler room is smaller than the recommended size, the length can be reduced by 500 mm respectively.
*Design and specifications subject to change without prior notice.