We use cookies to improve your user experience and for web traffic statistics purposes. By continuing to use this website, you agree to our use of cookies. Our Privacy Policy & Cookie Policy contains more information on such use and explains how to disable cookies.

0 selected
Go to…
  • Solutions
  • Industries
    • Apparel & Fashion
    • Medical
  • Products
  • Blog
  • Support
    • Warranty Policy
    • Discontinued Products
    • Contact us
  • About Oshima
    • History
    • Vision & Mission
    • News & Events
    • Office Location
  • Fabric Inspection Machine
  • Fabric Relaxing & Shrinking
  • Fabric Spreading Machine
  • Fabric Cutting Machine
  • Ironing & Shaping Machine
  • Heat Press Machine
  • Fabric Fusing Machine
  • Seamless & Ultrasonic Machine
  • Shirt Folding Bagging Machine & Carton Equipment
  • Needle Detection & Weighing
  • Industrial Boilers
  • Garment Accessories Machinery
  • Solutions
MENU
( )
  • English
  • 繁體中文
(0)
(0)
CLOSE
English 繁體中文
  • Solutions
  • Industries
    • Apparel & Fashion
    • Medical
  • Products
    • Fabric Inspection Machine
    • Fabric Relaxing & Shrinking
    • Fabric Spreading Machine
    • Fabric Cutting Machine
    • Ironing & Shaping Machine
    • Heat Press Machine
    • Fabric Fusing Machine
    • Seamless & Ultrasonic Machine
    • Shirt Folding Bagging Machine & Carton Equipment
    • Needle Detection & Weighing
    • Industrial Boilers
    • Garment Accessories Machinery
    • Solutions
  • Blog
  • Support
    • Warranty Policy
    • Discontinued Products
    • Contact us
  • About Oshima
    • History
    • Vision & Mission
    • News & Events
    • Office Location

Shopping list(0)

CLOSE
Subtotal: -
Checkout

Inquiry list(0)

CLOSE
Go to inquiry

Gas-Fired Boiler

  • Home
  • Products
  • Industrial Boilers
  • Gas-Fired Boiler
  • LSS Vertical Gas-Fired Steam Boiler
1 / 2
LSS Vertical Gas-Fired Steam Boiler
High-Efficiency Vertical Boiler for Space-Limited Industrial Use
  • PriceNT
  • Our price:NT
  • Use bonus pointspt.
Description:
The LSS internal combustion gas-fired boiler is a vertical, compact steam solution designed for factories with limited installation space. Its internal combustion structure combines a gas-fired furnace with vertically arranged water tubes, enabling efficient heat transfer and stable steam generation. With thermal efficiency ≥92%, the system ensures consistent steam output while reducing fuel consumption. The vertical design minimizes footprint, making it ideal for small to medium manufacturing facilities where space optimization is critical. Equipped with automatic controls for pressure, temperature, and water level, the boiler supports stable daily operation with minimal manual intervention. Its pre-assembled structure simplifies installation and maintenance, reducing downtime and operational complexity. This boiler is suitable for industries requiring reliable steam supply in compact environments, including garment manufacturing, food processing, and small-scale industrial production.
    Feature

    • Combustion & steam performance
      • Internal combustion design for efficient heat transfer
      • Fast cold start and quick pressure recovery
      • Stable and continuous steam output

    • Efficiency & energy saving
      • Thermal efficiency ≥92%
      • Optimized fuel consumption for lower operating cost
      • Suitable for small to medium industrial applications

    • Control & operation
      • Automatic control of pressure, temperature, and water level
      • Minimal manual operation required
      • Stable performance for daily factory use

    • Compact design & installation
      • Vertical structure for space-saving installation
      • Pre-assembled unit for quick setup
      • Easy maintenance with reduced downtime
    Specification
    左右滑動看表格
    Model
    LSS-0.2-0.7-Y、Q(|||) LSS-0.3-0.7-Y、Q(|||) LSS-0.5-0.7-Y、Q(|||) LSS-0.75-0.7-Y、Q(|||) LSS-1-1.0-Y、Q(|||)
    Specification Rated evaporation kg/h 200 300 500 750 1000
    Rated steam pressure MPa 0.7 1
    Rated steam temperature ℃ 170 184
    Boiler full water volume L 130 150 250 290 380
    Design thermal efficiency % ≥ 92
    Heated surface Ontology m2 6.2 7.53 8.93 10.66 12.86
    Economizer(Atmospheric) m2 2.51 14.64 19.52
    Fuel consumption Natural gas Nm³/h 15.67 23.51 38.76 58.14 78.87
    Pipe Main steam valve diameter DN 40 50
    Water inlet diameter DN G3/4" G1"
    Safety valve diameter DN G11/2" 40
    Blowoff valve diameter DN 40
    Chimney Φ 250 300
    Overall size Weight kg 959 1022 1500 1900 2300
    Length mm 1350 1840 1890 2000
    Width mm 1200 1690 1750 1850
    Height mm 2257 2407 2552 2708 2790
    Design and specifications subject to change without prior notice.
    Related products
    • LSG Biomass Combustion
    Back to the top
    • Our price:NT
    • PriceNT

    SOLUTIONS

    • Multi-Industry Automatic Fabric Cutting Solutions
    • Medical Garment Machinery Solutions
    • Setting New Standards in Garment Quality Inspection
    • Simplify Packaging Processes

    PRODUCT

    • Fabric Inspection Machine
    • Fabric Relaxing & Shrinking
    • Fabric Spreading Machine
    • Fabric Cutting Machine
    • Shirts Ironing & Shaping
    • Fabric Fusing Machine
    • Seamless & Ultrasonic Garment Machinery
    • Shirt Folding Bagging Machine & Carton Equipment
    • Needle Detection & Weighing
    • Industrial Boilers
    • Garment Accessories Machinery

    SUPPORT

    • Blog
    • Warranty Policy
    • Discontinued Products
    • YouTube

    CAREERS

    • Careers with us!

    ABOUT OSHIMA

    • About Us
    • Vision & Mission
    • Office Location
    • News & Events
    • Office to Rent
    • Contact Us
    Send
    >Cancel
    Oshima.com | Cookie Policy | Term of Use |Privacy Policy|Site Map
    Copyright © 2026 OSHIMA Taiwan Co. Ltd. All rights reserved.
    256 bit SSL Encryption
    Design by WebTech Webpage design